Property Address:
36 Wellington Avenue
North Vancouver, BC
![]() |
| Date: 09/01/2006 | Time: 11:00 AM | Report ID: 011106-02 |
| Property: 36 Wellington Avenue North Vancouver, BC |
Customer: Jason Matthews |
Real Estate Professional: Dave Rawlins |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
| Age Of Home: Over 25 Years | Client Is Present: Yes | Weather: Clear |
| Temperature: 5 Centigrade | Rain in last 3 days: Yes |
| Roof Covering: Cedar | Viewed roof covering from: Ground and from upstairs windows. | Sky Light(s): None |
| Chimney (exterior): Brick |
| IN | NI | NP | RR | ||
| 1.0 | ROOF COVERINGS | X | |||
| 1.1 | FLASHINGS | X | |||
| 1.2 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS | X | |||
| 1.3 | ROOF DRAINAGE SYSTEMS | X | |||
| IN | NI | NP | RR | ||
![]() |
![]() |
![]() |
![]() |
| Siding Style: Lap | Siding Material: Horizontal lapped Cedar siding | Exterior Entry Doors: Wood |
| Driveway: Concrete |
| IN | NI | NP | RR | ||
| 2.0 | GRADING | X | |||
| 2.1 | WALL CLADDING FLASHING AND TRIM | X | |||
| 2.2 | DOORS (Exterior) | X | |||
| 2.3 | WINDOWS | X | |||
| 2.4 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES, PATIO/ COVER AND APPLICABLE RAILINGS | X | |||
| 2.5 | VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIO FLOOR | X | X | ||
| 2.6 | EAVES, SOFFITS AND FASCIAS | X | |||
| 2.7 | ADDITIONAL BUILDINGS ON PROPERTY | X | |||
| 2.8 | FENCES | X | |||
| 2.9 | WALKWAYS AND RETAINING WALLS | X | |||
| IN | NI | NP | RR | ||
![]() |
![]() | ![]() |
![]() | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| Garage Door Type: Two automatic | Garage Door Material: Compressed board | Auto-opener Manufacturer: GENIE |
| IN | NI | NP | RR | ||
| 3.0 | GARAGE CEILINGS | X | |||
| 3.1 | GARAGE WALLS (INCLUDING FIREWALL SEPARATION) | X | |||
| 3.2 | GARAGE FLOOR | X | |||
| 3.3 | GARAGE DOOR (S) | X | |||
| 3.4 | OCCUPANT DOOR FROM GARAGE TO INSIDE HOME | X | |||
| 3.5 | GARAGE DOOR OPERATORS | X | |||
| IN | NI | NP | RR | ||
![]() |
| Ceiling Materials: Drywall | Wall Material: Drywall | Floor Covering(s): Carpet Tile |
| Interior Doors: Hollow core | Window Types: Double glazed insulated | Window Manufacturer: UNKNOWN |
| Cabinetry: Laminate | Countertop: Laminate |
| IN | NI | NP | RR | ||
| 4.0 | CEILINGS | X | |||
| 4.1 | WALLS | X | |||
| 4.2 | FLOORS | X | |||
| 4.3 | STEPS, STAIRWAYS, BALCONIES AND RAILINGS | X | |||
| 4.4 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS | X | |||
| 4.5 | DOORS (REPRESENTATIVE NUMBER) | X | |||
| 4.6 | WINDOWS (REPRESENTATIVE NUMBER) | X | |||
| 4.7 | CENTRAL VACUUM | X | |||
| 4.8 | LAUNDRY EQUIPMENT | X | |||
| IN | NI | NP | RR | ||
![]() |
| Foundation: Poured concrete | Wall Structure: Wood | Columns: Wood |
| Roof Structure: 2 X 8 Rafters | Roof-Type: Gable | Method used to observe attic: From entry |
| Attic info: Attic access |
| IN | NI | NP | RR | ||
| 5.0 | FOUNDATIONS, BASEMENTS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) | X | |||
| 5.1 | WALLS (Structural) | X | X | ||
| 5.2 | COLUMNS OR PIERS | X | |||
| 5.3 | FLOORS (Structural) | X | |||
| 5.4 | CEILINGS (structural) | X | |||
| 5.5 | ROOF STRUCTURE AND ATTIC | X | |||
| IN | NI | NP | RR | ||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| Water Source: Public | Water Filters: None | Plumbing Water Supply (into home): Galvanized (old) |
| Plumbing Water Distribution (inside home): Copper | Plumbing Waste: ABS | Water Heater Power Source: Gas |
| Water Heater Capacity: 40 Gallon (1-2 people) |
| IN | NI | NP | RR | ||
| 6.0 | PLUMBING DRAIN, WASTE AND VENT SYSTEMS | X | |||
| 6.1 | PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES | X | |||
| 6.2 | HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS | X | |||
| 6.3 | MAIN WATER SHUT-OFF DEVICE | X | |||
| 6.4 | FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) | X | |||
| 6.5 | MAIN FUEL SHUT OFF | X | |||
| 6.6 | TOILETS | X | |||
| 6.7 | SHOWERS | X | |||
| 6.8 | BATHS | X | |||
| 6.9 | BATHROOM HAND BASINS | X | |||
| 6.10 | KITCHEN SINK | X | |||
| 6.11 | EXTERIOR OUTLETS | X | |||
| IN | NI | NP | RR | ||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| Electrical Service Conductors: Below ground | Panel capacity: 100 AMP | Panel Type: Circuit breakers |
| Branch wire 15 and 20 AMP: Copper | Wiring Methods: Romex |
| IN | NI | NP | RR | ||
| 7.0 | SERVICE ENTRANCE CONDUCTORS | X | |||
| 7.1 | METER BASE | X | |||
| 7.2 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS | X | |||
| 7.3 | BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE | X | |||
| 7.4 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | X | |||
| 7.5 | POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE | X | |||
| 7.6 | OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS) | X | |||
| 7.7 | LOCATION OF MAIN AND DISTRIBUTION PANELS | X | |||
| 7.8 | SMOKE DETECTORS | X | X | ||
| 7.9 | CARBON MONOXIDE DETECTORS | X | |||
| 7.10 | COVER PLATES | X | |||
| IN | NI | NP | RR | ||
![]() |
![]() |
![]() | ![]() |
![]() |
![]() |
| Heat Type: Radiant base boards | Energy Source: Gas | Number of Heat Systems (excluding wood): Two |
| Types of Fireplaces: Solid Fuel | Operable Fireplaces: Two | Number of Woodstoves: None |
| IN | NI | NP | RR | ||
| 8.0 | HEATING EQUIPMENT | X | |||
| 8.1 | NORMAL OPERATING CONTROLS | X | |||
| 8.2 | SAFETY CONTROLS | X | |||
| 8.3 | DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | X | |||
| 8.4 | PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM | X | |||
| 8.5 | CHIMNEYS, FLUES AND VENTS (for fireplaces, gas water heaters or heat systems) | X | |||
| 8.6 | SOLID FUEL HEATING DEVICES (Fireplaces, Woodstove) | X | |||
| 8.7 | GAS/LP FIRELOGS AND FIREPLACES | X | |||
| 8.8 | COOLING AND AIR HANDLER EQUIPMENT | X | |||
| 8.9 | NORMAL OPERATING CONTROLS | X | |||
| 8.10 | PRESENCE OF INSTALLED COOLING SOURCE IN EACH ROOM | X | |||
| IN | NI | NP | RR | ||
![]() |
![]() |
![]() |
![]() | ![]() |
![]() |
| Attic Insulation: Batt | Ventilation: Soffit Vents | Exhaust Fans: None |
| Dryer Power Source: 220 Electric | Dryer Vent: Flexible Vinyl |
| IN | NI | NP | RR | ||
| 9.0 | INSULATION IN ATTIC | X | |||
| 9.1 | INSULATION UNDER FLOOR SYSTEM | X | |||
| 9.2 | VENTILATION OF ATTIC AND FOUNDATION AREAS | X | |||
| 9.3 | VENTING SYSTEMS (Kitchens, baths and laundry) | X | |||
| 9.4 | VENTILATION FANS AND THERMOSTATIC CONTROLS (ATTIC) | X | |||
| IN | NI | NP | RR | ||
![]() |
![]() |
![]() |
| Exhaust/Range hood: NONE |
| IN | NI | NP | RR | ||
| 10.0 | DISHWASHER | X | |||
| 10.1 | RANGES/OVENS/COOKTOPS | X | |||
| 10.2 | RANGE HOOD | X | |||
| 10.3 | TRASH COMPACTOR | X | |||
| 10.4 | FOOD WASTE DISPOSER | X | |||
| IN | NI | NP | RR | ||
![]() |
![]() Able Property Inspections Ltd. 604-987-5854 |
Customer |
Property Address |
| 1.0 | ROOF COVERINGS | |
| Repair or Replace | ||
|
The roof covering is old Cedar. While no evidence of leaks were observed it will require repair and extensive regular ongoing maintenance. |
||
| 1.3 | ROOF DRAINAGE SYSTEMS | |
| Repair or Replace | ||
|
Rain water pipes empty onto the roof. This is a poor practice that will lead to excessive roof wear. The rain water drains should be extended to drain into the lowest gutter. |
||
| 2.1 | WALL CLADDING FLASHING AND TRIM | |
| Repair or Replace | ||
|
Paint repairs required |
||
| 2.2 | DOORS (Exterior) | |
| Repair or Replace | ||
|
Gap in side door to garage. Repair required. |
||
| 2.5 | VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIO FLOOR | |
| Inspected, Repair or Replace | ||
|
Damaged/disconnected drain. The ground drain located at the rear of home will need periodical cleaning and maintenance. |
||
| 2.8 | FENCES | |
| Repair or Replace | ||
|
Weathered fence. Extensive repairs required. |
||
| 2.9 | WALKWAYS AND RETAINING WALLS | |
| Repair or Replace | ||
|
Cracked walkways can be a tripping hazard. Repairs required to seal cracks. |
||
| 3.4 | OCCUPANT DOOR FROM GARAGE TO INSIDE HOME | |
| Repair or Replace | ||
|
The occupant door from inside garage to inside the home is not a fire rated door. This means that should a fire occur in garage, the occupant door does not afford fire protection. This door should be replaced with a fire rated door. This door also requires a door closer to reduce the risk of Carbon Monoxide fumes from entering the house. |
||
| 4.2 | FLOORS | |
| Repair or Replace | ||
|
Uneven sloping floor over garage. |
||
| 4.5 | DOORS (REPRESENTATIVE NUMBER) | |
| Repair or Replace | ||
|
Dining room pocket door is not hanging plumb. Door jamb is not level. Repair required. |
||
| 4.7 | CENTRAL VACUUM | |
| Repair or Replace | ||
|
Central vacuum ducting is installed but no vacuum is installed. |
||
| 5.1 | WALLS (Structural) | |
| Inspected, Repair or Replace | ||
|
The room over the garage has a sloping floor possibly as a result of building settlement. No structural cracks were observed on the walls but the door jambs to this room were not level. This is for your information only, as a repair would be impractical and costly. |
||
| 6.6 | TOILETS | |
| Repair or Replace | ||
|
Loose toilets. Tightening required |
||
| 6.9 | BATHROOM HAND BASINS | |
| Repair or Replace | ||
|
One basin has a stuck plug that does not open. Another has a faulty tap that only runs cold. Repairs required. |
||
| 6.10 | KITCHEN SINK | |
| Repair or Replace | ||
|
Loose tap at sink |
||
| 6.11 | EXTERIOR OUTLETS | |
| Repair or Replace | ||
|
The outside water faucet is loose, and needs securing to wall at the rear of home. |
||
| 7.1 | METER BASE | |
| Repair or Replace | ||
|
Moisture has condensed inside the meter base cover obscuring visibility. Repair required. |
||
| 7.2 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS | |
| Repair or Replace | ||
|
The main panel has breakers that need labels identifying their location(s). Breaker wiring appears OK. |
||
| 7.4 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | |
| Repair or Replace | ||
|
Boiler wiring requires a junction box. A qualified electrician should carry out these repairs. |
||
| 7.8 | SMOKE DETECTORS | |
| Inspected, Repair or Replace | ||
|
Smoke detector required to ground floor. |
||
| 7.10 | COVER PLATES | |
| Repair or Replace | ||
|
Missing cover plate. This s a safety issue. |
||
| 8.0 | HEATING EQUIPMENT | |
| Repair or Replace | ||
|
Chimney Cleaning required if wood fireplace is to be used. |
||
| 8.1 | NORMAL OPERATING CONTROLS | |
| Repair or Replace | ||
|
The Boiler shut off switch is not working. The switch wiring appears to be disconnected. Repairs required by a qualified electrician. |
||
| 8.2 | SAFETY CONTROLS | |
| Repair or Replace | ||
|
The Boiler shut off switch is not working. The switch wiring appears to be disconnected. Repairs required by a qualified electrician. |
||
| 9.0 | INSULATION IN ATTIC | |
| Repair or Replace | ||
|
Attic access cover requires insulation inside attic. |
||
| 9.3 | VENTING SYSTEMS (Kitchens, baths and laundry) | |
| Repair or Replace | ||
|
(1) No ventilation fan is installed for the bathroom upstairs. Normally an exhaust fan is needed for proper ventilation. I recommend installing a ventilation fan. Lower bathroom has vent but it no working fan. |
||
This inspection was performed in accordance with and under the terms of a Pre-Inspection Agreement. The agreement was signed and agreed upon before the preparation of this report and a signed copy of the agreement is available upon request. An unsigned copy of the agreement may be attached to this report for your information or it may also be available on the home inspection company web site.